Share

Monash University researchers have developed new ‘time reversal’ technology which could revolutionise power line repairs.

The technology can rapidly locate faults in power networks, reducing the duration of power outages and helping to ease community impact in areas at risk of bushfires.

A new patent for this technology has been filed at Monash University, and expressions of interest from Australian industry to upscale for further testing have been received. 

This technology, which could go global, helps existing technology to prevent fires.

An international research team has successfully tested their fault location technology in Switzerland, with further trials to continue on Australian power lines.  

In contrast to current methods, this technology requires only a single measurement point installed at a substation which can identify a precise fault in the power line, to within ten metres, in a few seconds to minutes.

Victoria currently adopts Rapid Earth Fault Current Limiters (REFCLs) across its high-risk rural power networks, which limits the energy supply when a fault occurs to mitigate any bushfire risks.

However, REFCLs cannot precisely determine where a fault is located, meaning restoration crews can spend hours patrolling hundreds of kilometres of power lines in order to find the problem before they can fix it.

Thousands of people can be without power for several hours in extreme heat wave conditions as a result of this time lag. Local communities welcome the reduction in fire-risk, but can suffer heat stress casualties due to the long power outages that are sometimes required to prevent fires.

Research Associate in Monash University’s Department of Electrical and Computer Systems Engineering, Dr Tony Marxsen, said, “This innovation aims to ease the community impact of current technology that helps to prevent fires. The problem we have is when a network fault is detected, the REFCL activates to prevent the fire but it can’t find the fault.

“So what ends up happening is that a large number of people are without power for upwards of five hours on a 45 degree day.

“This technology offers the hope that faults can be pinpointed quickly, reliably and safely, to, above all, reduce the impact on customers in very high stress conditions.”

The ‘time reversal’ technology comprises three steps: firstly, the fault signals are measured; the fault locations are then defined and the time-reversed signals are injected to a computer model of the network; and, finally, the fault current at a guessed location is evaluated to identify the most probable location of the fault.

Dr Reza Razzaghi from Monash University’s Department of Electrical and Computer Systems Engineering, said, “Imagine a swimming pool with sensors around its perimeter. 

“If a stone was dropped into the water, the ripples would hit the sensors, and these sensors would record the waves generated by this stone drop. 

“The ‘time reversal’ technology can find the location of the dropped stone by (in a computer model of the pool) reversing the direction of the waves measured by the sensors.” 

The technology will allow distribution network operators to locate faults in power lines quickly and allow the fault to be found and repaired faster.

Faults in electrical distribution networks are one of the primary sources of major bushfires in Australia. On Black Saturday, five of Victoria’s eleven major bushfires were started by power line faults. 

Media reports blamed a power network fault for a 2019 fire in South Australia that burned more than 20,000 hectares, destroying many houses and local businesses.

“Rather than bypassing REFCLs and re-energising faulty networks and risking a fire, this technology can help to pinpoint the fault location after the operation of REFCLs,” Dr Razzaghi said.

“This radical new technology has the potential to save lives and ensure Australia is best prepared to prevent and tackle any catastrophic incidents that might arise as our country continues to get warmer and drier,” Dr Marxsen said.

Further research is currently being undertaken to adapt this technology to Australian power networks.

The study, titled ‘Time reversal applied to fault location in power networks: Pilot test results and analyses’ was a collaboration between Dr Reza Razzaghi (Monash University), and Mr Zhaoyang Wang, Dr Mario Paolone and Dr Farhad Rachidi (Swiss Federal Institute of Technology Lausanne).  

Other partners on this project include the Monash Energy Institute, Monash GRID Innovation Hub, AusNet Services and IND Technology.

Related articles
0 Comments

Leave a reply

Your email address will not be published. Required fields are marked *

*


The reCAPTCHA verification period has expired. Please reload the page.

©2024 Energy Magazine. All rights reserved

CONTACT US

We're not around right now. But you can send us an email and we'll get back to you, asap.

Sending

Log in with your credentials

Forgot your details?